How blast-resistant glazing and doors are specified
The figures a blast specification needs, the test standards used, and how British Aluminium matches a design to a project blast study in Saudi Arabia, Qatar and the GCC.
Start with the load
A blast-resistant opening is specified by the load it must resist, taken from the project blast study or security assessment. Three figures describe it: the peak pressure (in kPa, psi or bar), the impulse (in kPa·ms) and the duration (in ms). State whether the pressure is incident or reflected.
The standards you will see
- EN 13123-1 and EN 13124-1: windows, doors and shutters tested in a shock tube, classes EPR1 to EPR4.
- EN 13123-2 and EN 13124-2: the same products tested in the open air with an explosive charge, classes EXR1 to EXR5.
- EN 13541: blast-resistant glass, classes ER1 to ER4.
- ASTM F1642 for glazing and ASTM F2247 for doors.
- UFC 3-340-02: the design method used to check structures and openings against a blast load.
What British Aluminium supplies
- Steel-framed windows, doors and partitions classified EPR1 by shock-tube test.
- Blast-resistant facades and glazed screens designed to the project load, up to 100 psi.
- Metal blast-resistant doors up to 7 bar.
- Sliding blast doors for large openings, 2 to 100 psi.
- The BA Blast Film and Anchor System for existing windows.
Why the whole opening matters
The glass, the frame, the fixings and the wall they anchor to all carry the load. We check the proposed assembly against the project blast load and confirm the anchorage for the wall construction on site.
Related
Have a project requirement?
Send your drawings, specification and project location. Tell us what the opening needs to achieve and where you need support.