Discuss a project →
Guides

Bullet-resistant glazing: explained and simplified

There is no such thing as bulletproof glass.

There is no such thing as bulletproof glass. There is only glazing certified against a specific round, fired at a specific velocity, from a specific distance, a specific number of times.

Everything about it comes down to two things: which weapon you are protecting against, and whether the glass is allowed to spray the person behind it.

The round sets the class — EN 1063

EN 1063 classifies the glazing itself. Each class is defined by a cartridge, bullet construction, mass, impact velocity and firing distance. Three shots are fired in a 120 mm triangle on a 500 × 500 mm specimen.

Full jacket, pointed, soft core with steel penetrator 4.0 g 950 m/s BR6 7.62 × 51 NATO (.308) Full jacket, pointed, soft core 9.5 g 830 m/s BR7 7.62 × 51 NATO Full jacket, pointed, hardened steel core 9.8 g 820 m/s SG1 12/70 shotgun Solid lead slug — single shot 31 g 420 m/s 3m SG2 12/70 shotgun Solid lead slug — three shots 31 g 420 m/s 3m Classes are cumulative in intent but not in construction: a build-up certified to BR6 will not necessarily pass BR7, because BR7 introduces a hardened steel core rather than simply more energy.

The American classes — UL 752

UL 752 classifies bullet-resisting equipment as tested — glazing, frames, doors, barriers and transaction units. Levels 1 to 3 are handgun, 4 to 5 are single-shot rifle, and 6 to 8 repeat the handgun and rifle threats at higher shot counts.

NIJ 0108.01

The NIJ standard for ballistic resistant protective materials is sometimes cited on government and law-enforcement work. It assesses penetration only — it does not evaluate spall.

The comparison columns in this guide are indicative only. EN 1063, UL 752 and NIJ 0108.01 use different ammunition, velocities, shot counts, specimen sizes and conditioning temperatures. A product certified to one is not certified to the others, and no cross-reference table substitutes for a test report.

Spall — the letters after the class

When a bullet strikes, the glazing may stop it and still throw fragments off the protected face. That debris is called spall, and at close range it can seriously injure the person the glazing was installed to protect. EN 1063 records it as a suffix.

Specified where staff sit or stand directly behind the glazing — bank counters, reception desks, guard houses, public service windows.

Splinters permitted on the protected side Acceptable where nobody is immediately behind the glazing, or where a set-back or secondary screen protects the occupant.

BR4 NS and BR4 S stop the same bullet. Only one of them is safe to stand behind. If a classification on a drawing carries no suffix, ask before pricing.

Glass alone, or the whole window

This catches out more specifications than anything else in the subject. The European system uses two different sets of letters depending on what was actually tested.

Aluminium or steel

We build certified ballistic systems in both. The right choice depends on the class required, the size of the opening and where the element sits in the building.

What else to think about

  • Thickness and weight. Ballistic glazing is heavy and thick, and both rise sharply with the class. This drives frame depth, hardware, hinges, structural loading and how the units are lifted into place. It is a co-ordination issue, not just a product choice.
  • Doors need more than glass. Hinges, locks, closers and the frame all have to be part of the tested assembly. A ballistic leaf on standard ironmongery is not a ballistic door.
  • Attack from one side only. Ballistic classes are tested from the threat side. Which face that is must be stated, and it must be installed that way round.
  • Ballistic is not blast, and not forced entry. Separate standards, separate tests, separate build-ups. A ballistic rating confers none of the others.
  • Sight and speech. Counters and reception positions usually need a transaction detail — a tray, a pass-through or a speech panel — designed as part of the certified assembly.

The four things that go wrong most often

Both stop the bullet. Only one is safe to stand behind Specifying BR when FB was meant BR is the glazing alone. The frame, seals and fixings are untested and become the weak point Treating EN, UL and NIJ classes as interchangeable Different ammunition, velocities, shot counts and conditioning.

The range at British Aluminium

We supply the complete range across both certification systems — EN and UL — in aluminium and in steel, as certified assemblies rather than separately rated parts.

Aluminium and steel framed glazing, doors and public counters EN 1522 / EN 1063 · UL 752 / NIJ 0108.01 Acoustic systems 80 mm and 100 mm double-glazed partitions, acoustic doors and screens EN ISO 10140 / EN ISO 717-1 · ASTM E90 / E413 / E1332 Combined performance Fire with blast, ballistic with acoustic, and other multi-requirement assemblies Certified per configuration The easiest way to start: tell us the class you need, whether spall is acceptable, and send the elevation and door and window schedule. We will confirm which of our aluminium or steel systems meets it, and flag the weight and structural implications before anything is priced.

Issued for information. Selection of the threat level and the required ballistic class is the responsibility of the project's security consultant and the authority having jurisdiction. This document does not constitute security engineering advice. Ammunition data and cross-system comparisons are indicative; classification is established only by test to the governing standard. Standards are cited as at the date shown and this guide is revised without notice; always work from the current issue.

The full guide

This page gives the text of our technical guide. The tables, charts and quick-reference sheet are in the PDF: download the full guide.

Related

Have a project requirement?

Send your drawings, specification and project location. Tell us what the opening needs to achieve and where you need support.