SBC 201 follows the IBC approach. Every opening in a rated wall needs an opening protective with its own rating, which is often lower than the wall: a 2-hour exit stair, for example, takes a 90-minute door. Fire-rated glazing has size limits and must carry a permanent marking, and fire doors and windows are installed to NFPA 80. SBC 801 then requires them to be kept in working order for the life of the building.

By Josh Astin, British Aluminium · Updated 27 November 2026

What this means in practice

Expect the consultant to ask for listed and labelled assemblies, a marking on every lite of glass, and door hardware listed for fire doors. Glazing over the fire-protective limits needs fire-resistive glazing tested as a wall. Doors in exit stairs must self-close and latch.

EN-tested products in Saudi projects

Products tested to EN standards are used on Saudi projects, but the specification and the approving authority decide what is accepted for each element. Agree it before pricing, record it in a tender clarification, and keep the classification reports ready for the Civil Defense submittal.

What to ask the bidder

  • What rating does the fire strategy give each opening?
  • Is evidence accepted as UL/NFPA, EN, or both?
  • Will every lite carry a permanent marking or certification label?

Questions people ask

Does a 2-hour wall need a 2-hour door?

Not always. The opening table in the code sets the door rating.

Who keeps the doors working after handover?

The building owner, under SBC 801 and the Civil Defense licence conditions.

Related

About British Aluminium

British Aluminium designs and manufactures fire-rated, bullet-resistant, blast-resistant and anti-attack glazing, doors and windows in aluminium and steel. Made in the GCC, for projects in Qatar, Saudi Arabia, Oman and export markets. BA Academy is our series of short lessons for architects, consultants, contractors and procurement teams.