Discuss a project →
BA Academy

Security glazing glossary

Fire, bullet, blast and forced-entry terms in plain words.

Short definitions of the fire, bullet, blast and forced-entry terms used when specifying security glazing and doors.

E (integrity)
Fire class: the assembly holds back flames, smoke and hot gases for the stated minutes (EN 13501-2).
EW (integrity + radiation)
Fire class: as E, and radiant heat on the protected side stays below 15 kW/m².
EI (integrity + insulation)
Fire class: as E, and the protected face rises no more than 140 °C on average and 180 °C at any point.
Intumescent
A material that swells when heated. Used in fire glass interlayers and in seals around glass and doors.
Standard fire curve
The furnace time-temperature curve in EN 1363-1 / ISO 834: about 945 °C at 60 minutes.
Classification report
The document that states the fire, bullet or blast class of a tested assembly and what it covers.
BR1–BR7
EN 1063 bullet-resistance classes for glass, from .22 LR (BR1) to 7.62 mm rifle with hard-core ammunition (BR7).
SG1 / SG2
EN 1063 shotgun classes for glass.
S / NS
Splintering / non-splintering: whether glass fragments come off the protected side when the glass is shot.
FB1–FB7, FSG
EN 1522/1523 bullet-resistance classes for complete windows, doors, shutters and blinds.
UL 752
US standard for bullet-resisting equipment, with Levels 1 to 10.
Spall
Fragments thrown off the back of glass or another material when it is hit.
ER1–ER4
EN 13541 blast-resistance classes for glass, tested in a shock tube.
ISO 16933
Blast test of glazing in an open-air arena with a real charge, giving a hazard rating.
ISO 16934
Blast test of glazing in a shock tube, giving a hazard rating.
Hazard rating
How much glass enters the room in a blast test: A (no break), B (no hazard), C (minimal), D (very low), E (low), F (high hazard).
Standoff distance
The distance between a possible explosive charge and the building. More distance means a lower load.
Peak pressure and impulse
The two numbers that describe a blast load on a facade.
Glass bite
How far the edge of the glass sits inside the frame.
P1A–P5A
EN 356 attack-resistant glass classes tested by steel ball drop.
P6B–P8B
EN 356 attack-resistant glass classes tested by axe attack.
RC1–RC6
EN 1627 burglar-resistance classes for complete doors and windows, by attacker toolset and minutes of resistance.
LPS 1175
LPCB security rating: toolkit letter A–H plus delay minutes 1–20, e.g. C5 or D10 (Issue 8).
Multi-threat glazing
A glazing unit built and tested to resist more than one threat, such as fire and bullets.

← All BA Academy lessons

Have a project requirement?

Send your drawings, specification and project location. We will tell you which tested system fits.